Home Page
UL / CSA Certified 600W RF Power Supply up to 60 MHz - RF-600-LD
Important Notice
This is our archived version of MTI old website. Price, inventory, and technical information IS NOT accurate. Please do not use them as factors for purchasing decisions. Please navigate our new web MTI's New Website. Thank you for your understanding! |
|
|
Please call for the delivery time
Item Number: RF600
|
The RF-600-LD power supply is available in six standard frequencies. It supplies standard power up to 600 W. Frequencies are adjustable from 400 kHz to 60 MHz. This unit is designed to meet the safety compliance requirements of EN 61010-1:2010, UL 61010-1:2012, and CSA C22.2 No. 61010-1:2012. Certified compliant systems carry the TUV mark for safety and/or EMC to all appropriate latest international standards.
SPECIFICATIONS
| Electrical Specification |
| AC Input Voltage |
- 208VAC; no neutral; 1 phase with ground.
|
| AC Line Frequency |
|
| AC Input Current: |
|
| Output Characteristics: |
- Up to 600W continuous forward power at the unit’s rear bulkhead RF connector into a 50 Ohm load. The forward power out is to track the command set-point for any load conditions where the reflected power is less than 100W.
|
| Accuracy/Regulation |
- ±2W or ±1.0% of set-point, whichever is greater, from 10% to 100% max output, as measured by either the actual output power and/or the forward analog readback signal.
|
| Short Term Stability |
- ±1.0% for output power set-point (10-100%) during one continuous hour of output.
|
| Long Term Stability |
- ±3.0% for output power set-point (10-100%) during 3 years of continuous output.
|
| Rise Time |
- Less than 200ms; from leading edge of enable signal to 90% of power level requested
|
| Zero Set-point |
- Less than 1.0W actual output power and less than 1.0W read back power when the set-point signal is at zero or at a negative
|
| Available frequencies |
- 400kHz, 2MHz, 13.56MHz, 27.12MHz, 40.68MHz, 60MHz
|
| Frequency stability |
|
| Output Filtering (for full power into 50 Ohms) |
- Harmonic Signals: Less than -40dBc
|
- Spurious Signals: Less than -40dBc
|
- AM & FM Noise (@ 50 KHz offset): Less than -40dBc
|
| Signals and Connections |
| Signal Input Impedance |
|
| Signal Input Isolation |
- 1000 VDC minimum to the A/C supply line.
|
| Input Power Connection |
- Harting HAN 5Q rear panel bulkhead connector.
|
- Mating connector:
- shell: Comdel JI0952, Harting 09200030427, strain relief: Comdel JI0950, Harting09000005082
- insert: Comdel JI0958, Harting 09120053101, female pin: Comdel JI0957, Harting 09330006202
|
- 15 pin sub miniature "D" type (female) receptacle.
|
| Control I/O Connector |
| DeviceNet Connector |
- 5 pin micro style (male).
|
| Output Power Connector |
- Type "N" female coaxial connector.
|
| RS232 Connector |
- 9 pin subminiature "D" type (female) receptacle.
|
Mechanical
|
| RF Unit Dimensions |
- 8.5"W x 5.25"H x 18.5"D ( 21.6cm x 13.4cm x 46.9cm)
|
| Weight |
|
| Mounting |
- Standard 19" EIA rack mounting with ½ rack filler panel.
|
| Environmental |
| Operating Temperature & Humidity: |
- +10 to +40° C (50 to 104° F) ambient, 5-85% R.H. (non-condensing, no formation of ice), 86-106 kPa. Temperature, humidity and air pressure operating range class 3K3 per prEN50178.
|
| Inlet Air Requirements: |
|
| Coolant Type: |
|
| Storage temperature/humidity/air pressure |
- -25 to +70° C (class 1k4 per EN50178), 5 - 95% humidity (non-condensing, no formation of ice, class 1k3), 70-106 kPa (class 1k4).
|
| Transport temperature/humidity/air pressure |
- -25 to +70° C, 5 - 95% humidity, 70-106 kPa
|
| Regulatory Compliance |
- This unit is designed to meet the safety compliance requirements of EN 61010-1:2010, UL 61010-1:2012, and CSA C22.2 No. 61010-1:2012. Certified compliant systems carry the TUV mark for safety and/or EMC to all appropriate latest international standards.
|
- This unit is designed and tested for full functionality through all SEMI F47-0200 voltage sag immunity events.
|
- The unit is designed to meet Samsung Power Vaccine requirements.
|
| Warranty |
- One year limited with lifetime support
|
|
|
MTI sponsorships: MTI Sponsors Thermoelectrics Workshop
MTI-UCSD Battery Fabrication Lab
MTI Sponsors the Postdoctoral Awards